【国外标准】 Standard Test Method for Measuring Heat Transfer Rate Using a Thin-Skin Calorimeter
本网站 发布时间:
2024-02-28
- ASTM E459-22
- Active
选择类型:
电子版: 646元
/ 折扣价:
550 元
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This test method may be used to measure the net heat transfer rate to a metallic or coated metallic surface for a variety of applications, including:5.1.1 Measurements of aerodynamic heating when the calorimeter is placed into a flow environment, such as a wind tunnel or an arc jet; the calorimeters can be designed to have the same size and shape as the actual test specimens to minimize heat transfer corrections;5.1.2 Heat transfer measurements in fires and fire safety testing;5.1.3 Laser power and laser absorption measurements; as well as,5.1.4 X-ray and particle beam (electrons or ions) dosimetry measurements.5.2 The thin-skin calorimeter is one of many concepts used to measure heat transfer rates. It may be used to measure convective, radiative, or combinations of convective and radiative (usually called mixed or total) heat transfer rates. However, when the calorimeter is used to measure radiative or mixed heat transfer rates, the absorptivity and reflectivity of the surface should be measured over the expected radiation wavelength region of the source, and as functions of temperature if possible.5.3 In 6.6 and 6.7, it is demonstrated that lateral heat conduction effects on a local measurement can be minimized by using a calorimeter material with a low thermal conductivity. Alternatively, a distribution of the heat transfer rate may be obtained by placing a number of thermocouples along the back surface of the calorimeter.5.4 In high temperature or high heat transfer rate applications, the principal drawback to the use of thin-skin calorimeters is the short exposure time necessary to ensure survival of the calorimeter such that repeat measurements can be made with the same sensor. When operation to burnout is necessary to obtain the desired heat flux measurements, thin-skin calorimeters are often a good choice because they are relatively inexpensive to fabricate.5.5 It is important to understand that the calorimeter design (that is, that shown in Fig. 1) will measure the “net” heat flux into the thin-skin calorimeter. This configuration may or may not be the same as the test specimen of interest. If it is the same configuration, then the results from use of Eq 1 can be used directly. But if the configuration is different, then some additional analysis should be performed. For example, if the actual test specimen has an insulated layer on the inside surface of the thin-skin, but the thin-skin calorimeter does not, then the net heat flux from Eq 1 will not be the same as the response of the test specimen. Refer to Appendix X1 for further discussion of this topic.1.1 This test method covers the design and use of a thin metallic calorimeter for measuring heat transfer rate (also called heat flux). Thermocouples are attached to the unexposed surface of the calorimeter. A one-dimensional heat flow analysis is used for calculating the heat transfer rate from the temperature measurements. Applications include aerodynamic heating, laser and radiation power measurements, and fire safety testing.1.2 Advantages: 1.2.1 Simplicity of Construction—The calorimeter may be constructed from a number of materials. The size and shape can often be made to match the actual application. Thermocouples may be attached to the metal by spot, electron beam, or laser welding.1.2.2 Heat transfer rate distributions may be obtained if metals with low thermal conductivity, such as some stainless steels or Inconel 600, are used.1.2.3 The calorimeters can be fabricated with smooth surfaces, without insulators or plugs and the attendant temperature discontinuities, to provide more realistic flow conditions for aerodynamic heating measurements.1.2.4 The calorimeters described in this test method are relatively inexpensive. If necessary, they may be operated to burn-out to obtain heat transfer information.1.3 Limitations: 1.3.1 At higher heat flux levels, short test times are necessary to ensure calorimeter survival.1.3.2 For applications in wind tunnels or arc-jet facilities, the calorimeter must be operated at pressures and temperatures such that the thin-skin does not distort under pressure loads. Distortion of the surface will introduce measurement errors.1.3.3 Interpretation of the heat flux estimated may require additional analysis if the thin-skin calorimeter configuration is different from the test specimen.1.4 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4.1 Exception—The values given in parentheses are for information only.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E459-22
标准名称:
Standard Test Method for Measuring Heat Transfer Rate Using a Thin-Skin Calorimeter
英文名称:
Standard Test Method for Measuring Heat Transfer Rate Using a Thin-Skin Calorimeter标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- 国家标准计划
- BS EN 14625:2024 Ambient air. Standard method for the measurement of the concentration of ozone by ultraviolet
- BS EN 14626:2024 Ambient air. Standard method for the measurement of the concentration of carbon monoxide by non
- BS EN 14211:2024 Ambient air. Standard method for the measurement of the concentration of nitrogen dioxide
- BS EN 14212:2024 Ambient air. Standard method for the measurement of the concentration of sulphur dioxide
- BS EN 4869-103:2024 Aerospace series. Expanded beam termini, fibre optic non-physical contact in EN 3645 standard
- BS EN 4869-104:2024 Aerospace series. Expanded beam termini, fibre optic non-physical contact in EN 3645 standard
- 24/30506654 DC BS ISO 20038 Banking and related financial services — Key wrap using advanced encryption standard
- BS EN 4869-001:2024 Aerospace series. Expanded beam termini, fibre optic non-physical contact in EN 3645 standard
- BS EN 4869-101:2024 Aerospace series. Expanded beam termini, fibre optic non-physical contact in EN 3645 standard
- BS EN 4869-102:2024 Aerospace series. Expanded beam termini, fibre optic non-physical contact in EN 3645 standard
- BS ISO 27729:2024 - TC Tracked Changes. Information and documentation. International standard name identifier (ISNI)
- BS ISO 23603:2024 - TC Tracked Changes. Standard method of assessing the spectral quality of daylight simulators
- 24/30505086 DC BS EN IEC 61400-16 Standard file format for sharing power curve information
- BS ISO 27729:2024 Information and documentation. International standard name identifier (ISNI)
- 24/30504596 DC BS EN IEC 63147 Standard criteria for accident monitoring instrumentation for nuclear power